The importance of analysis

Eastman offers a sample analysis program to our customers. This service helps ensure your fluids remain within in-service limits, allowing you to identify potential issues early on and avoid potentially costly issues later.

During flight, hydraulic fluid can be influenced by environmental factors that may alter its properties, such as heat, moisture and cleanliness. We will assess your fluid’s viability following exposure to these conditions to support your operational needs.

Four Skydrol cans sit on a surface.
A man stands next to several cans of Skydrol that rest on a surface.

Skydrol sample analysis program

Skydrol customers can use our sample analysis program at no extra cost. Specific guidelines must be met to ensure quality and safety. This program provides free Skydrol sample kits that include:

  • Sample bottle (Nalgene, HDPE)
  • Label
  • Plastic bag (polyethylene)
  • Carton box

Prohibited items notice

Because of safety concerns, these items will be discarded if received:

  • Glass bottles
  • Bottles that have leaked; one-click lids are not suitable.

Guidelines

A person holds a brochure about the Skydrol sample analysis program.
Skydrol cans come down a belt on a production line.

These steps are general guidelines for obtaining a proper sample while ensuring the safety and quality of the results.

  • Pressurize and operate the hydraulic system for 10 to 15 minutes.
  • Wipe off the sampling port with a lint-free cloth.
  • Allow about 250 mL (1 pint) of fluid to drain to purge any settled particles from the sampling port.
  • Fill the bottle and cap immediately.
  • Close the drain valve.
  • Fill out the sample label.
  • Service system reservoirs to replace the fluid that was removed.

Sample return instructions by region

 

North America and Latin America

Eastman Chemical Company
Anniston plant ATTN: Skydrol lab
702 Clydesdale Ave.
Anniston, AL 36201
Tel: 256-231-8449

Local guidelines

Europe, Africa and Middle East

Eastman Chemical Company (Solutia UK Ltd)
FAO: Fluids testing
QA lab Corporation Road Newport, U.K.
NP19 4XF

Local guidelines

Asia Pacific

Ship Skydrol samples to the following address via courier services. Use this exact delivery address. Do not include Eastman in the delivery address, or your sample will be delayed.

You can use our SGS agent in place of chief chemist only if the freight forwarder requires a name: Eric Wang, Eric-AY.Wang@sgs.com, 86-18317189173

SGS-CSTC Standards Technical Services (Shanghai) Co., Ltd.
Attn: Chief chemist
Building C, No. 399, Shengxia Road, Pudong New District, 201210
Shanghai, China
86-18317189173

Local guidelines

Fluid color specifications


Phosphate ester-based aviation hydraulic fluids are purple when new but may change color during service. Color is not a reliable indicator of quality. There is no in-service specification for fluid color. Rather, fluid should be free of cloudiness or suspended solids.